The Verification Jig in Multiple Implant-Supported Prostheses within the Digital Workflow: A Scoping Review

Main Article Content

Johnathan de Souza Miranda
Giovani Flach
Matheus Pinós
Eduardo Mukai

Abstract

Passive fit is a mandatory prerequisite for the long-term mechanical stability of implant-supported full-arch prostheses, yet accurately transferring the three-dimensional implant position to the working cast or digital file remains the central technical challenge in this field. This scoping review, registered a priori on the Open Science Framework (DOI 10.17605/OSF.IO/VPKA7) and reported per PRISMA-ScR, mapped the methods, materials, and positional indexing devices, particularly the verification jig, used in multiple implant-supported full-arch prostheses within the digital workflow. PubMed/MEDLINE, Scopus, and Web of Science were searched without date or language restrictions. Of 4,341 records identified, 16 studies published between 2002 and 2025 were included. Five evaluated conventional resin jigs; the only clinical study among them associated jig use with 100% passive fit versus 14% without it. Eight studies evaluated digital scan aids, whose benefit depended on scanner optical technology, and one retrospective study validated a calibrated splinting framework with 100% passive fit and 97.8% one-year prosthetic survival. One study established an RMS error threshold below 62.2 µm as a virtual biomechanical safety parameter. The verification jig, whether conventional, CAD/CAM-milled, or functionally replaced by scan aids and calibrated frameworks, continues to be necessary for passive fit in most scenarios, based on current evidence, even within a fully digital workflow.

Article Details

Section

Review

Author Biographies

Johnathan de Souza Miranda, Department of Dentistry, São Leopoldo Mandic University

Department of Dentistry, São Leopoldo Mandic University, São Paulo, Brazil. 

Giovani Flach, Department of Dentistry, São Leopoldo Mandic University

Department of Dentistry, São Leopoldo Mandic University, São Paulo, Brazil.

Matheus Pinós, Department of Dentistry, São Leopoldo Mandic University

Department of Dentistry, São Leopoldo Mandic University, São Paulo, Brazil.

Eduardo Mukai, Department of Dentistry, São Leopoldo Mandic University

Department of Dentistry, São Leopoldo Mandic University, São Paulo, Brazil. 

How to Cite

The Verification Jig in Multiple Implant-Supported Prostheses within the Digital Workflow: A Scoping Review. (2026). Brazilian Journal of Dentistry Oral Radiology, 5(1), bjd73. https://doi.org/10.52600/2965-8837.bjdor.2026.5.bjd73

Similar Articles

You may also start an advanced similarity search for this article.